Heater wattage calculator
Estimate the heater power for a process: what it takes to heat up, what it takes to keep running, and the size to specify. Results update as you type.
Loads and settings
Everything that has to be brought up to temperature before the process runs: the product, the tank or tooling, and the losses while it heats.
The load once the process is running: product passing through each cycle, plus the losses that never stop. Give each material a mass per cycle and a cycle time.
Have the power and need the current? Open the Ohm’s law calculator →
Worked example
Heat 100 kg of water from 25 °C to 80 °C in 30 minutes. What power is needed, before losses and margin?
- Inputs: m = 100 kg, cp = 4.18 kJ/kg·K, ΔT = 80 − 25 = 55 K, t = 30 min = 1,800 s.
- Formula: P = m × cp × ΔT × 1000 ÷ t.
- P = 100 × 4.18 × 55 × 1000 ÷ 1,800 = 12,772 W = 12.77 kW.
Press “Load example” to see this case with a stainless steel tank, a shared wall loss and a continuous load added.
Equations used
Heat to raise temperature, where m is mass, cp specific heat, ΔT the temperature rise and t the heat-up or cycle time in seconds:
Heat to melt or vaporise, where h is the latent heat:
Flat-wall conduction loss, where k is thermal conductivity, A wall area, L wall thickness in metres:
ΔTwall is the hot-side minus cold-side temperature. During start-up it is the average difference, if you enter one.
Mass from volume: m = volume × density. Sizing estimate:
Stages run separately: Pbasis is the larger of start-up and continuous power, each including shared losses. Stages run together: Pbasis = start-up only + continuous only + shared losses once. 1 W = 3.412 BTU/h.
Assumptions and limits
- Preset properties are typical values at the condition shown under each preset, held constant over your temperature range. Edit them to match your data.
- Start-up power is the average over the heat-up time. All materials in the Start-up tab share that time.
- Wall loss is steady conduction through one flat layer between the two surface temperatures you enter. During start-up it uses the full difference unless you enter an average.
- A shared loss is one you mark yourself. It is included in both stage totals, and counted once, at its larger value, when the stages run together. Loads are never matched automatically.
- Surface convection and radiation, open liquid surfaces, evaporation, and losses through fittings and supports are not calculated. Add them as a known load in watts, or allow for them in the margin.
- Melting or vaporising covers the change of state only. Add a separate row to heat the material up to that temperature.
- A margin of 10% suits a well-defined system; 20% to 35% is usual when several values are estimated.
- The result is total heater power. Watt density, sheath material and control still have to be chosen for the application.